sysdat.fm
System Data
System-Specific Capacity Limits for HiPath 3000, HiPath 5000
Table 2-26
HiPath 3000/5000 - System-Specific Capacity Limits (Maximum Configuration)
System
HG 1500 boards
Gateway channels to the system
1
System load is greatly dependent on factors such as system configuration and traffic. Static rules on configuration inspec-
tion are therefore not suitable. As a guide, configurations that include UCD/ACD, more than one SLC16N, groups with
more than 10 stations or OpenScape Office connections should always be inspected using the project planning tool
/enterprise-businessarea.siemens-enterprise.com/productinfo/document/9fTFkWdA76U_/Hi-
Path%203000%20V8%20Planungsanleitung%20Performance%20Calculation%20Tool.xls).
2
Only configurations that do not exceed this limit will be supported.
3
Up to 96 stations can be TDM stations.
4
Up to 61 of the 96 stations can be TDM stations (4xanalog T/R + 1xU
the central board + 3xSLU8R or 3x8SLAR or 3xSLAD8R).
5
Up to 41 of the 96 stations can be TDM stations (4xa/b + 5xU
board + 1x16SLA).
6
Up to 33 of the 96 stations can be TDM stations (4xa/b + 5xU
board + 1xSLU8R or 1x8SLAR or 1xSLAD8R).
7
These are administrative capacity limits.
8
Due to the power consumption of HG 1500, a UPSC-D must be used.
9
Due to the power consumption of HG 1500, a UPSC-DR must be used.
10 If the total number of U
an external power supply unit (Powerbox PB3000 with LUNA2) must be used.
11 4xa/b + 1xU
+ 7xBS/32xHiPath Cordless Office stations at the central board + 5xSLU8R or 5x8SLAR or 5xSLAD8R.
P0/E
12 4xa/b + 5xU
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2x16SLA.
P0/E
13 4xa/b + 5xU
+ 3xBS/16xHiPath Cordless Office stations at the central board + 2xSLU8R or 2x8SLAR or 2xSLAD8R.
P0/E
14 4xa/b at the central board + 5x8SLAR or 5xSLAD8.
15 4xa/b at the central board + 2x16SLA.
16 4xa/b at the central board + 2x8SLAR or 2xSLAD8.
17 8xU
at the central board + 5xSLU8 + 1xSLMO24.
P0/E
18 8xU
at the central board + 5xSLU8R.
P0/E
19 8xU
at the central board + 2xSLU8.
P0/E
20 8xU
at the central board + 2xSLU8R.
P0/E
21 If the total number of U
DR must be used.
22 Due to the 5-V power supply unit, one SLC16N and a maximum of two HG 1500 V3.0 boards can be used.
23 64 HiPath Cordless Office stations at the SLC16N or 32 HiPath Cordless Office stations at the central board.
24 The system may be configured with two HG 1500 boards if PDM1 is not used.
2-44
stations, analog stations and additional stations connected using an adapter is greater than 72,
P0/E
stations and additional stations connected using an adapter is greater than 24, UPSC-D/UPSC-
P0/E
HiPath
HiPath
HiPath
1
3800
3550
3500
8
3
128
48
+ 7xBS/32xHiPath Cordless Office stations at
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
P0/E
+ 3xBS/16xHiPath Cordless Office stations at the central
P0/E
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation