Introduction and Important Notes
safety information and warnings
1.2.4

Safety Information for Australia (for Australia only)

Music on Hold and paging devices must be connected to the HiPath 3000 via an ACA ap-
proved Line Isolation Unit.
HiPath 3550 and HiPath 3350 must be installed near the mains socket outlet, which is pow-
ering the system. The mains socket shall be readily accessible. Integrity of the main socket
must be assured.
HiPath 3000 and HiPath 5000 may only be installed and maintained by authorized service
personnel.
HiPath 3550 and HiPath 3350 must be earthed with a separate bonding earth, if the sys-
tems are powered by a UPS.
CE (customer equipment) does not continue to support emergency dialing after loss of
mains power, if battery back up and power fail switchover to emergency analog phones is
not available.
HiPath 3000/5000 must always be programmed to allow the dialing of emergency numbers
(for example 000).
1.2.5

Safety Information for Brazil (for Brazil only)

The use of the outlet strip with overvoltage protection with part number C39334-Z7052-C33 is
absolutely mandatory. The AC power of the HiPath 3000 systems must be conducted through
the outlet strip with overvoltage protection.
It is absolutely necessary to use a shielded Ethernet cable for LAN interfaces/ports of the
HXGS3 board.
1.2.6

Notes

Note the following information in order to avoid damage to property:
Before placing the system into operation, check whether the nominal voltage of the power
supply network corresponds to the nominal voltage of the communication system or device
(type plate). If necessary, adjust the nominal voltage of the communication system or de-
vice appropriately.
To protect electrostatically sensitive devices (ESD):
Always wear the wristband in the prescribed manner before performing any work on
PC boards and modules.
Transport PC boards and modules only in suitable protective packaging.
Always place PC boards and modules on a grounded conductive base, and do not
work on the PC boards anywhere else.
1-12
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation