9
Interference Tests
Connection Diagram
Parameters
Dependencies
Results
292
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.4.3-SQ-RX Squelch Exit Voltage (VSQ) test.
The parameters used in Expert Mode for this test, are as follows:
•
Data Rate
•
Target BER
•
IBerReader Init Mode
•
Squelch Test Sequence
•
Re-Init sequence after Reset DUT
•
ISI Trace
•
Min Value
•
Max Value
•
Step Size
•
Set Single Ended Amplitude
•
Tested Offsets
•
Number of Pulses
•
Pulse Distance
•
Pulse Width
•
Min Interference Amplitude
•
Max Interference Amplitude
•
Steps Interference Amplitude
These parameters are listed in alphabetical order in
The calibrations required for this test are as follows:
•
Reference Clock Calibration
•
Level Calibration Terminated / Into Open
•
Interference Calibration
An example of a HTML Viewer for the SQ-RX Squelch RF Interference
Tolerance Test procedure is shown in
the following:
Figure
170. The results comprise of
Keysight N5990A MIPI M-PHY Receiver Test User Guide
Table
6.