Procedure; Connection Diagram; Parameters; Dependencies - Keysight Technologies N5990A User Manual

Mipi m-phy receiver test
Table of Contents

Advertisement

Procedure

Connection Diagram

Parameters

Dependencies

Keysight N5990A MIPI M-PHY Receiver Test User Guide
This test is similar to the previous Test 2.1.8 but in this case, the data
generator sends Continuous-Mode CJTPAT signaling instead of
Burst-Mode, and the DUT is configured to receive the Continuous-Mode
CJTPAT in Terminated mode. For more details refer to the Procedure
section of the Test 2.1.8-HS-RX Frequency Offset Tolerance (fOFFSET-RX)
during HS Burst).
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.1.1- HS-RX Differential Input Voltage Amplitude Test.
The parameters used in Expert Mode for this test, are as follows:
CDR Loop Bandwidth (if CDR is selected in the Special Parameter
dialog, see
"BERT Analyzer
CDR Peaking (if CDR is selected in the Special Parameter dialog, see
"BERT Analyzer
Settings")
CDR Transition Density (if CDR is selected in the Special Parameter
dialog, see
"BERT Analyzer
CDR Loop Order (if CDR is selected in the Special Parameter dialog,
see
"BERT Analyzer
Target BER
BerReader Init Mode
Test Sequence
Lane Under Test Termination Model
Level Pairs
Tested Offset
Tested Range
These parameters are listed in alphabetical order in
The calibrations required for this test are as follows:
Reference Clock Calibration
Level Calibration Terminated
Settings")
Settings")
Settings")
HS Tests
5
Table
6.
193