Parameter Name
Result
PWM Data Rate
Termination Time Min
Termination UI Min
Min Spec
Termination Time Max
Termination UI Max
Max Spec
Keysight N5990A MIPI M-PHY Receiver Test User Guide
Enable Time (T
TERM-ON-PWM-RX
Table 43
Test 2.2.4-PWM-RX Differential Termination Enable Time (TTERM-ON-PWM-RX) Test
data table
Parameter Description
"Pass"/"Fail" - If the value is "Fail", the termination enable time is not within the spec limit.
It is the PWM data rate value in MBit/s.
It is the shortest/minimum termination enable time in "ns" (nanosecond).
It is the shortest/minimum termination enable time in "UI".
It is the minimum value of the termination enable time, where the DUT must work according to the
specification.
It is the maximum termination enable time in "ns".
It is the maximum termination enable time in "UI".
It is the maximum value of the termination enable time, where the DUT must work according to the
specification.