Procedure; Connection Diagram; Parameters - Keysight Technologies N5990A User Manual

Mipi m-phy receiver test
Table of Contents

Advertisement

Procedure

Connection Diagram

Parameters

Keysight N5990A MIPI M-PHY Receiver Test User Guide
The data generator sends Burst-mode CJTPAT signaling while the DUT is
configured for Terminated-mode.
In Compliance Mode, the calibrated Level Pairs (V
set to four different test cases: nominal differential voltage and maximum
common-mode (V
DIF-RX
differential voltage and minimum common-mode (V
V
= 25mV); maximum differential voltage and maximum
CM-RX
common-mode (V
DIF-RX
differential voltage and minimum common-mode (V
V
= 25mV). At each step, the BER is measured and compared with
CM-RX
the Target BER to consider the pass/fail result.
In Expert Mode, the common-mode voltage component of each Level Pair
is tested over the given Offset Range. In this case, the result will show the
minimum and maximum offset values at which the DUT works properly and
the test will pass if those values are within the spec limits.
This test is performed for all selected HS lanes and gears (see
The Unterminated case is not tested because of the difficulties with
measuring and calibrating while using the unterminated signaling. In
Unipro Test Mode, with the option "Lane Test Mode" set to
Simultaneously, the different lanes are tested in parallel for each gear.
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.1.1- HS-RX Differential Input Voltage Amplitude Test.
The parameters used in Expert Mode for this test, are as follows
CDR Loop Bandwidth (if CDR is selected in the Special Parameter
dialog, see
"BERT Analyzer
CDR Peaking (if CDR is selected in the Special Parameter dialog, see
"BERT Analyzer
Settings")
CDR Transition Density (if CDR is selected in the Special Parameter
dialog, see
"BERT Analyzer
CDR Loop Order (if CDR is selected in the Special Parameter dialog,
see
"BERT Analyzer
Target BER
IBerReader Init Mode
= 150mV and V
CM-RX
= 245mV and V
CM-RX
Settings")
Settings")
Settings")
HS Tests
and V
) are
DIF-RX
CM-RX
= 330mV); nominal
= 150mV and
DIF-RX
= 330mV); minimum
= 60mV and
DIF-RX
Figure
5
98).