Procedure; Connection Diagram; Parameters - Keysight Technologies N5990A User Manual

Mipi m-phy receiver test
Table of Contents

Advertisement

Procedure

Connection Diagram

Parameters

Keysight N5990A MIPI M-PHY Receiver Test User Guide
The data generator sends Burst-mode CJTPAT signaling while the DUT is
configured for Terminated-mode. The differential voltage amplitude and
the common-mode are set to the nominal values (200mV). No other signal
impairments such as the ISI channel or the jitter sources are added to the
signal.
A sweep of the calibrated Lane-to-Lane skew is done in the tested lane,
starting with the Min Tested Value (minimum skew value) and increasing
with the given Step Size value until the Max Tested Value is reached. At
each step the BER is measured and compared with the Target BER to
consider the pass/fail result.
This test is performed at each selected lane and PWM gear and it is tested
at the minimum and maximum data rate value for all gears.
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.1.6-HS-RX Lane-to-Lane Skew Test test.
The parameters used in Expert Mode for this test, are as follows:
Level Pairs
CDR Loop Bandwidth (if CDR is selected in the Special Parameter
dialog, see
"BERT Analyzer
CDR Peaking (if CDR is selected in the Special Parameter dialog, see
"BERT Analyzer
Settings")
CDR Transition Density (if CDR is selected in the Special Parameter
dialog, see
"BERT Analyzer
CDR Loop Order (if CDR is select in Special Parameter dialog, see
"BERT Analyzer
Settings")
Target BER
IBerReader Init Mode
Test Sequence
Re-Init sequence after Reset DUT
Min Spec
Min. Tested Value
Max. Tested Value
Step Size
Settings")
Settings")
PWM Tests
7
253