Changes For Xml300 With Sn > 3000; Operating Software Version 3.31 - Kodak X-Omat MULTILOADER 300 Plus Service Manual

Hide thumbs Also See for X-Omat MULTILOADER 300 Plus:
Table of Contents

Advertisement

ML300 SN > 3000
8. Changes for XML300 with SN > 3000
This section describes the differences between KODAK X-OMAT MULTILOADER 300 with SN
< 3000 and SN > 3000.

OPERATING SOFTWARE version 3.31.

ERROR CODES
To ease the error code recording, the display of the error code is improved.
Old type of error CODE:
New Type of ERROR CODE:
The letter above the error code is the abbreviation of the associated unit.
The error code shown above should be recorded as C69.
FUNCTION CASSETTE OPEN/RETURN
Note
In case of problems set this PARAMETER to 00.
The function to return an empty CASSETTE open can be disabled with a PARAMETER. To
disable it SERVICE SOFTWARE 3.30 or higher is required. The name of this PARAMETER is:
The following settings are possible:
KODAK AG, Stuttgart
0069000000
S
C
M
I
00
69
00
00
LETTER
S
C
M
I
P
CASS OPEN RETURN.
00 = DEFAULT
00 = An empty CASSETTE is closed before it is transported out.
01 = An empty CASSETTE will be returned open.
P
00
UNIT
SYSTEM UNIT
CASSETTE UNIT
MAGAZINE UNIT
INTERFACE UNIT