ADJUSTMENTS
60.
Manually rotate the FILM POCKET SUCKER BAR out of the MAGAZINE.
Note
Do not leave on the SOLENOID Y14 for too long. It will become very hot.
61.
Test the position of the BLOW PIPE HOLES (SLITS in the old version) in relation
to the FILM POCKET SUCKERS. To do this the COMPRESSOR must be switched on,
SOLENOID VALVE Y12 must be energised and SOLENOID TILTING MAGAZINE
SUCKER BAR Y14 must be switched on.
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select MAGAZINE MOTORS ............................................................................ press ENTER
Select COMPRESSOR M16 ............................................................................... press ENTER
Select MOTOR ON
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select SOLENOID VALVES................................................................................ press ENTER
Select MAGAZINE SUCKING Y12.................................................................... press ENTER
Select SOL: VALVE ON ..................................................................................... press ENTER
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select SOLENOIDS ............................................................................................. press ENTER
Select TILTING MAGAZINE SUCKER BAR Y14............................................... press ENTER
Select SOLENOID ON
62.
Place the BLOWPIPE POSITIONER GAUGE TL 4582 onto the FILM POCKET
SUCKERS.
KODAK AG, Stuttgart
BLOW PIPE POSITIONER
figure 3-50