SM 3058-6
15.
If the distance of 21.3mm is not correct, loosen the MOUNTING SCREW of the
PCB HOLDER and move it as required.
Note
Not all PCB A10 are working correctly when the gap is set to 1.2 mm. Especially with the
old style PCBs the gap should not be bigger than 0.5 mm.
16.
If the distance of 1mm is not correct, loosen the MOUNTING SCREWS of PCBA10
and move it as required.
17.
If the PCB cannot be moved far enough, take it out and elongate the MOUNTING
SCREW HOLES with a small file.
FUNCTION TEST
1
.
Feed in a CASSETTE.
2
.
Check that the HOLDING FINGER transports the CASSETTE up to the CASSETTE
END STOP.
3
.
Check that the correct CASSETTE SIZE is detected.
9/98
2-12
REPLACEMENTS
KODAK AG, Stuttgart