Note
It is very important to STORE PARAMETERS. If this is not done only the DISPLAY of the
LAP TOP shows the new values. However they are not transferred into the battery backed up
memory of the ML300.
Select STORE PARAMETER ............................................................................... press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML300 SERVICE MODE ............................................................... press ENTER
Select Quit the program ................................................................................. press ENTER

CASSETTE UNIT

VACUUM OFF TIME

PURPOSE:
To turn off the CASSETTE SUCKERS VACUUM at the correct time.
The CASSETTE SUCKER BAR picks up the exposed FILMS from the CASSETTE. As soon
as SENSOR B20 VACUUM OFF detects the LEADING EDGE of the FILM, the VACUUM OFF
TIME is started. When this time is terminated the vacuum is released and the FILM is picked
up by the TRANSPORT ROLLERS.
1 increment = 10 msec
RANGE:
DEFAULT:
1
.
Start CHANGE PARAMETER.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU ....................................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed............................................ press ENTER
UNIT DATA are displayed ................................................................................ press ENTER
Select CHANGE ML300 DATA from the MAIN MENU ............................... press ENTER
Select CHANGE PARAMETER .......................................................................... press ENTER
Select VACUUM OFF TIME
Key in the new value....................................................................................... press ENTER
Select STORE PARAMETER ............................................................................... press ENTER
2
.
Exit the SERVICE PROGRAM.
Press BACKSPACE twice
Select QUIT ML300 SERVICE MODE ............................................................... press ENTER