PREVENTIVE MAINTENANCE

HUMIDIFIER (MOD 42)

Warning
·
Follow the how-to-use and the safety instructions supplied with the disinfectant.
·
The HUMIDIFIER CARTRIDGE must not be replaced by the CUSTOMER. To replace it
the left-hand SIDE PANEL must be removed
1
.
To reduce the potential for biological growth and contamination within the ML300
HUMIDIFIER, the water reservoir should be drained and the cleaned with a disinfectant.
The FILTER 9198261 should be replaced at least every 6 month. The biological growth
and contamination are not originated by the HUMIDIFIER. They are caused by the
outside air and the water. They are then accumulated in the FILTER. The disinfectant
has to be bought locally.
2
.
To replace the HUMIDIFIER CARTRIDGE take off the left-hand SIDE PANEL.
Carefully lift the CARTRIDGE out - it is soaked with water - and remove it in the
direction of the FRONT PANEL. Water from the soaked CARTRIDGE must not drop into
the ELECTRONICS.
KODAK AG, Stuttgart
figure 10-5
10-7