ADJUSTMENTS
67.
To do the adjustment of the SENSOR B61, place the BLOW PIPE POSITION
TOOL TL-4582 onto the MAGAZINE SUCKERS and start the SENSOR TEST.
Press BACKSPACE twice to come back to the screen COMPONENT TEST
Select SENSORS .................................................................................................. press ENTER
Select SENSOR TEST WITH SOUND.................................................................. press ENTER
68.
Carefully press down the tool onto the SUCKERS. After 0.2 - 0.5 mm, SENSOR
B61 should be actuated.
69.
If the SENSOR is not actuated, carefully bend the ACTUATOR BRACKET.
70.
Exit the SENSOR TEST.
Press BACKSPACE twice to come back to the screen COMPONENT TEST
71.
Insert an empty MAGAZINE into position 3.
72.
Check that the BLOW PIPES have the correct distance to the MAGAZINE.
KODAK AG, Stuttgart
CAREFULLY BEND HERE. BUT ONLY IF NECESSARY!
Both ACTUATORS must touch the tool at the same time.
figure 3-52
3-53
SM 3058-6
9/98