SM 3058-6
ADJUSTMENT SENSOR B24
PURPOSE:
To avoid false error code C74 if SENSOR B2/C_IN_R2 is triggered by hand or if a curved
CASSETTE is pulled out.
Note
To enable SENSOR B24/C_IN_R2 SWITCH S2 on PCB A( must be in the upper position.
1
.
Open the TOP COVER of the ML300.
2
.
Start the SENSOR TEST
Key in START ........................................................................................................ press ENTER
Select SERVICE MODE ML300......................................................................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed............................................ Press ENTER
UNIT DATA are displayed ................................................................................ press ENTER
Select COMPONENT TEST ................................................................................ press ENTER
Select SENSORS .................................................................................................. press ENTER
Select SENSOR TEST with sound ..................................................................... press ENTER
9/98
figure 3-83
3-94
ADJUSTMENTS
KODAK AG, Stuttgart