ML300 SN > 2000
SERVICE CALLS
In the DIAGNOSTICS MANUAL DG 3058 12/92 pages 2-1, 2-2 and 2-3 all error codes
declared as SERVICE CALLS are given.
With the new software this listing is no longer valid.
With the new OPERATING SOFTWARE the following error codes are declared as SERVICE
CALLS only:
SYSTEM UNIT
FF
CES set the XML300 to the inoperative mode. FF does not become cleared
automatically on leaving the SERVICE PROGRAM. To reset it select:
OPTION CHANGE ML300 DATA
then
OPTION ENABLE/DISABLE ML300
CASSETTE UNIT
DB
Software not compatible (occurs during software download only)
FF
CES set the XML300 to the inoperative mode. FF does not become cleared
automatically on leaving the SERVICE PROGRAM. To reset it select:
OPTION CHANGE ML300 DATA
then
OPTION ENABLE/DISABLE ML300
MAGAZINE UNIT
96
The FILM POCKET did not reach the SELECTED MAGAZINE LEVEL in the correct
time and a time-out occurred. Only valid for SERIAL UNLOAD.
98
The FILM POCKET reached the END SWITCH but not the CASSETTE LEVEL. Only
valid for SERIAL UNLOAD.
DB
Software not compatible (occurs during software download only)
FF
CES set the XML300 to the inoperative mode. FF does not become cleared
automatically on leaving the SERVICE PROGRAM. To reset it select:
OPTION CHANGE ML300 DATA
then
OPTION ENABLE/DISABLE ML300
INTERFACE UNIT
FF
CES set the XML300 to the inoperative mode. FF does not become cleared
automatically on leaving the SERVICE PROGRAM. To reset it select:
OPTION CHANGE ML300 DATA
then
OPTION ENABLE/DISABLE ML300
PROCESSOR UNIT
FF
CES set the XML300 to the inoperative mode. FF does not become cleared
automatically on leaving the SERVICE PROGRAM. To reset it select:
OPTION CHANGE ML300 DATA
then
OPTION ENABLE/DISABLE ML300
KODAK AG, Stuttgart
7-17
SM 3058-6
9/98