ADJUSTMENTS
push here
Note
The SOLENOID Y7 will be switched ON for 59 seconds. This time is limited to avoid
overheating of the SOLENOID.
3
.
Tilt the CASSETTE SUCKER BAR.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU ....................................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed............................................ press ENTER
UNIT DATA are displayed ................................................................................ press ENTER
Select COMPONENT TEST from the MAIN MENU ....................................... press ENTER
Select SOLENOIDS ............................................................................................. press ENTER
Select TILTING CASSETTE SUCKER BAR Y7.................................................... press ENTER
Select SOLENOID ON
4
.
Manually move the CASSETTE SUCKER BAR CARRIAGE forward until the
CASSETTE SUCKERS reach the ADJUSTMENT PLATE 9193386.
KODAK AG, Stuttgart
figure 3-17
3-17
SM 3058-6
9/98