ADJUSTMENTS
11
. Set the edge of LOWER LIMIT to a distance of 86 ±0.5 mm to the BASE PLATE.
12
. Fasten the MOUNTING SCREWS.
13
. Start the SCAN RUN.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU ....................................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed............................................ press ENTER
UNIT DATA are displayed ................................................................................ press ENTER
Select change ML300 DATA from the MAIN MENU ................................. press ENTER
Select CHANGE PARAMETER .......................................................................... press ENTER
Select SCAN RUN .............................................................................................. press ENTER
Select STORE PARAMETERS ............................................................................. press ENTER
14.
Do the NEARLY EMPTY adjustment.
Select NEARLY EMPTY ....................................................................................... press ENTER
15.
Exit the SERVICE MODE
Select STORE PARAMETERS ............................................................................. press ENTER
Press BACKSPACE twice
Select QUIT ML300 SERVICE MODE ............................................................... press ENTER
Select Quit the program ................................................................................. press ENTER
16.
Check the FILM POCKET ADJUSTMENT.

NEARLY EMPTY ADJUSTMENT

PURPOSE:
This adjustment finds automatically the correct value of NEARLY EMPTY.
Note
An empty MAGAZINE has to be used for this procedure.
1
.
Start the NEARLY EMPTY ADJUSTMENT
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU ....................................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed............................................ press ENTER
UNIT DATA are displayed ................................................................................ press ENTER
Select CHANGE ML300 DATA from the MAIN MENU ............................... press ENTER
Select CHANGE PARAMETER .......................................................................... press ENTER
Select NEARLY EMPTY ....................................................................................... press ENTER
KODAK AG, Stuttgart
3-71
SM 3058-6
9/98