ADJUSTMENTS
3
.
Loosen both SENSOR MOUNTING SCREWS.
4
.
Turn the GAIN ADJUSTMENT SCREW of SENSOR B24 fully clockwise.
5
.
Move the SENSOR up and down until its infrared beam is reflected by the reflective
foil. This turns the INDICATOR LED green.
6
.
Fasten both SENSOR MOUNTING SCREWS.
KODAK AG, Stuttgart
MOUNTING SCREW (2)
INDICATOR LED
INFRARED BEAM
REFLECTIVE STICKER
HOLDING FINGER MOTOR
GAIN ADJUSTMENT
SENSOR B24
figure 3-84
3-95
SM 3058-6
SCREW
9/98