REPLACEMENTS
8
.
Take out SPRINGS.
9.
Disconnect the VACUUM SOLENOID CONNECTOR.
10
. Disconnect the GROUND WIRE at the ROLLER MOTOR.
11
. Disconnect the CONNECTORS of both CARRIAGE POSITION SENSORS.
12
. Disconnect the CONNECTOR of the SENSOR VACUUM OFF.
Note
Do not lose the SPACER of the PRESSURE ROLLER SHAFT located on the ROLLER
MOTOR side.
13
. Carefully lift out the CARRIAGE ASSEMBLY.
FUNCTION TEST
1
.
Check that the WIRE TIES are at the correct position. Use the marks from step 4 as
reference.
2
.
Check that the CONVEYOR is seated properly. It must be as far as possible to the
front (e.g. to the INPUT FLAP).
3
.
Run a TEST CYCLE.
4
.
Check that the FILM is picked up from the CASSETTE.
5
.
Check that the FILM is transported correctly into the FILM CHUTE.
6
.
Use various FILM SIZES.
KODAK AG, Stuttgart
2-49
SM 3058-6
9/98