SM 3058-6
If there is 1 FILM between the DETECTOR ROLLERS the light passes through the SLOT in
the DOUBLE FILM SENSOR ARM. During the adjustment this slot must be positioned
precisely over the light beam of the SENSOR B59.
If there is no FILM between the DETECTOR ROLLERS the path of light in SENSOR B59 is
interrupted by AREA 1 of the DOUBLE SHEET SENSOR ARM.
AREA 1
9/98
DETECTOR ROLLER
SLOT
AREA 2
ADJUSTMENT SCREW
figure 3-59
3-64
ADJUSTMENTS
KODAK AG, Stuttgart