M16C/62P Group (M16C/62P, M16C/62PT)
A/D Control Register 0
b7 b6 b5 b4
b3 b2 b1 b0
0
0
NOTES :
1.
If the ADCON0 register is rew ritten during A/D conversion, the conversion result w ill be indeterminate.
2.
AN0_0 to AN0_7, and AN2_0 to AN2_7 can be used in the same w ay as AN0 to AN7. Use the ADGSEL1 to
ADGSEL0 bits in the ADCON2 register to select the desired pin. How ever, if VCC2 < VCC1, do not use AN0_0 to
AN0_7 and AN2_0 to AN2_7 as analog input pins.
3.
After rew riting the MD1 to MD0 bits, set the CH2 to CH0 bits over again using another instruction.
A/D Control Register 1
b7 b6 b5 b4
b3 b2 b1 b0
1
0
NOTES :
1.
If the ADCON1 register is rew ritten during A/D conversion, the conversion result w ill be indeterminate.
2.
If the VCUT bit is reset from "0" (Vref unconnected) to "1" (Vref connected), w ait for 1 µs or more before starting
A/D conversion.
Figure 18.5
ADCON0 and ADCON1 Registers (One-shot Mode)
Rev.2.41
Jan 10, 2006
REJ09B0185-0241
http://www.xinpian.net
(1)
Symbol
Address
03D6h
ADCON0
Bit Symbol
Bit Name
Analog Input Pin Select Bit
CH0
CH1
CH2
MD0
A/D Operation Mode Select
(3)
Bit 0
MD1
Trigger Select Bit
TRG
A/D Conversion Start Flag
ADST
Frequency Select Bit 0
CKS0
(1)
Symbol
Address
03D7h
ADCON1
Symbol
Address
A/D Sw eep Pin Select Bit
SCAN0
SCAN1
A/D Operation Mode Select Bit 1 Set to "0" w hen one-shot mode is selected
MD2
8/10-Bit Mode Select Bit
BITS
CKS1
Frequency Select Bit 1
Vref Connect Bit
VCUT
External Op-Amp Connection
OPA0
Mode Bit
OPA1
Page 239 of 390
提供单片机解密、IC解密、芯片解密业务
(2, 3)
b2 b1 b0
0 0 0 : AN0 is selected
0 0 1 : AN1 is selected
0 1 0 : AN2 is selected
0 1 1 : AN3 is selected
1 0 0 : AN4 is selected
1 0 1 : AN5 is selected
1 1 0 : AN6 is selected
1 1 1 : AN7 is selected
b4 b3
0 0 : One-shot mode
0 : Softw are trigger
_________
1 : ADTRG
trigger
0 : A/D conversion disabled
1 : A/D conversion started
Refer to NOTE 3 for the ADCON2 Register
Invalid in one-shot mode
0 : 8-bit mode
1 : 10-bit mode
Refer to NOTE 3 for the ADCON2 Register
(2)
1 : Vref connected
b7 b6
0 0 : ANEX0 and ANEX1 are not used
0 1 : ANEX0 input is A/D converted
1 0 : ANEX1 input is A/D converted
1 1 : External op-amp connection mode
18. A/D Converter
After Reset
00000XXXb
Function
After Reset
00h
After Reset
010-62245566 13810019655
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW