6 Installation

6.2.5 Installation Orientation and Space

6.2.5

Installation Orientation and Space

Precautions for the mounting the Σ-V-SD driver, including the mounting orientation and mounting space, are
given below.
5 mm max.
5 mm min.
• Always install the power regeneration converter on the left side of the SERVOPACK.
• We recommend that you install the SERVOPACKs in order of capacity, with the SERVOPACK with the
largest capacity closest to the power regeneration converter.
• All of the Σ-V-SD drivers have external heat sinks for cooling.
• Refer to the external dimension diagrams for external dimensions and mounting dimensions of the products
(4.1.2 External Dimensions and 4.2.2 External Dimensions).
• Make sure that the ambient air temperature of the Σ-V-SD driver is 0 to 55°C near the heat sink and inside
the control panel at a 70% load, and 0 to 40°C inside the control panel at a 100% load.
• To prevent oil penetration, seal the mounting screw sections of the power regeneration converter and the
SERVOPACK.
• Always install the Σ-V-SD driver with the fan at the top to ensure efficient cooling.
• When mounting the Σ-V-SD driver, allow space above and below it to prevent heat buildup.
• When stirring the air inside the control panel, do not allow the airflow to fall directly on the Σ-V-SD driver
to prevent dirt from collecting on the Σ-V-SD driver.
• Provide the following spaces between the units.
6-12
5 mm max.
5 mm max.
5 mm min.
120 mm min.
Σ-V-SD Driver
120 mm min.
5 mm min.
Installation Orientation and Space for Σ-V-SD Driver
20.5 ± 0.3
10
Mounting hole
Unit
Air
Flow
Fan
Heat
Sink
Cooling Air
2.5 m/s min.
Unit: mm
(0.5)
10
Mounting hole
Unit
Ventilation
Duct