Number / Alarm
Cause
A123
See user manual for TB board
TB alarm 2
not Compact PLUS
A124
See user manual for TB board
TB alarm 2
not Compact PLUS
A125
See user manual for TB board
TB alarm 2
not Compact PLUS
A126
See user manual for TB board
TB alarm 2
not Compact PLUS
A127
See user manual for TB board
TB alarm 2
not Compact PLUS
A128
See user manual for TB board
TB alarm 2
not Compact PLUS
A129
Machine data 1 (position encoder type/axis
type) is 0 (axis does not exist).
Axis does not exist -
machine data 1 = 0
Effect:
Operation of the axis is inhibited and the
position controller is deactivated.
A130
The "in operation [IOP]" checkback signal was
missing when a traversing command was
Operating conditions
initiated. The following causes inhibit the "in
do not exist
operation" checkback signal (status bit No.2,
refer to function diagram sheet 200) :
-Control signals [OFF1], [OFF2], [OFF3]
and/or "enable controller" [ENC] are not
activated.
-Checkback signals [OFF2] and/or [OFF3] are
not activated.
-A fault [FAULT] is active.
Effect:
The traversing command is inhibited.
A131
Control signal [OFF1] was deactivated while a
traversing command was being executed.
OFF1 missing
Effect:
The drive is brought to a standstill via a ramp
(P464 Deceleration Time). There is a
subsequent pulse disable. This also valid if
P443 =0 (function diagramm 310) and the
ramp generator bypass (function diagramm
320) is used.
20
Counter-measure
See user manual for TB board
See user manual for TB board
See user manual for TB board
See user manual for TB board
See user manual for TB board
See user manual for TB board
You must assign a valid value to machine data
1 in order to operate the axis.
Activate control signals [OFF1], [OFF2],
[OFF3] and "enable controller" [ENC].
-If checkback signals [OFF2] and/or [OFF3]
are missing, check the supply of control word
1 (MASTERDRIVES function diagram, sheet
180).
-Analyze the queued fault number
[FAULT_NO], remedy the fault, and then
cancel the fault using the acknowledge fault
[ACK_F] control signal.
Note:
To activate the "in operation" [IOP] status
again, you must deactivate [OFF1] and then
activate it again.
Check the activation of control signal [OFF1]
from the user program.
6SE7087-6QX70 (Version AG)
Compendium Motion Control
05.2006