Binector number
B0826
B0827
B0828
B0829
B0830
B0831
B0832
B0833
B0834
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES
Binector name
ContSync Active
MastVCorVdifAct
Trig. MastV Cor
Fault Ref. F2
MasterV Cor Act
Ramp inactive
Start active
Stop active
Stop at tab end
Compendium Motion Control
Description
The synchronism function can be temporarily
deactivated via disable/enable synchronism at U674.1
or by call-up in the mode manager. Previously internal
values/statuses of synchronism were reset in the
process.
If the new "Continue synchronism" function is
activated via binector input U674.2, internal
values/statuses are frozen. No internal reset of
values/statuses takes place. Thus during temporary
deactivation synchronism behaves as if it had never
been deactivated.
Thus the following statuses remain:
- Table remains, does not return to X0.0.
- Synchronous status remains.
- Referenced status remains.
- Engage/disengage coupled remains.
- Synchronization, offset angle setting [FD 841] are
continued.
- Position correction, referencing [FD 841] are
continued.
Binector 826 in function diagram 846 indicates
activation of the "Continue synchronism" function.
This binector is active during speed adjustment
between V% master value 1 at U451.5 and V%
master value 2, i.e. as long as the differential speed at
KK866 is not 0.
[In function diagram 845b.8]
Trigger master-value correction is used with the
master-value correction function during homing to
compensate for the actual-value jump. To this end,
this binector can be connected to "Trigger master-
value correction" B0828, and "Absolute value master-
value correction" KK0308 can be connected to
"Correction displacement" U453.
Function diagram: 817 (845)
Error in homing proximity switch (printing index)
outside window 2
Fixed binector 0
In function diagram 15.2, 15.4
Engage mode: (n658 = 1)
0: Engage/disengage ramping
1: Engage active and in constant travel
Disengage mode: (n658 = 2)
0: Disengage ramping
1: Disengage active and at standstill
Function diagram [834a.7, 834b.7, 834c.7]
1: Engage procedure active (ramp and constant travel)
0: Engaging action inactive
Function diagram [834a.7, 834b.7, 834c.7]
1: Disengaging procedure active (ramp and constant
travel)
0: Disengaging inactive
Function diagram [834a.7, 834b.7, 834c.7]
1: Axis reached table function and table end
0: Table running, or no table function selected
13