Binector number
B0835
B0836
B0837
B0840
B0850
B0851
B0852
B0853
B0856
B0858
B0859
B0860
B0861
B0862
B0863
B0864
B0865
B0866
B0867
B0868
B0869
B0870
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES
Binector name
B SLE active
Sync in F1
Sync.in F2
Positioning act
BasicRFG1 POV
BasicRFG1 NOV
BasicRFG2 POV
BasicRFG2 NOV
Emerg/lowering
Uzk>max lower
Uzk< min lower
BPos POS OK
BPos POS_RUN
BPos RFG_RUN
BPos RU_ACT
BPos RD_ACT
BPos FWD_RUN
BPos BWD_RUN
BPos POS_DELTA
BPos_SW_E_PLUS
BPos_SW_E_MINUS
SET_EN_POS_REF
Compendium Motion Control
Description
Simulink encoder active
1 = synchronous in F2
The state of the synchronizing movement is
acknowledged by binectors (e.g. synchronizing speed
can thus be adjusted). The binector indicates that the
synchronizing difference is shown clearly in the
window.
1 = synchronous in F2
The state of the synchronizing movement is
acknowledged by binectors (e.g. synchronizing speed
can thus be adjusted). The binector indicates that the
synchronizing difference is shown clearly in the
window.
Binector "Additive offset active"
In function diagram 794.8
Binector output of the 1st basic ramp generator (32
bit) for displaying the upper limit active.
[FP786a]
Binector output of the 1st basic ramp generator (32
bit) for displaying the lower limit active.
[FP786a]
Binector output of the 2nd basic ramp generator (32
bit) for displaying the upper limit active.
[FP786b]
Binector output of the 2nd basic ramp generator (32
bit) for displaying the lower limit active.
[FP786b]
Fixed binector 0
In function diagram 15.2, 15.4
Fixed binector 0
In function diagram 15.2, 15.4
Fixed binector 0
In function diagram 15.2, 15.4
POS_OK (in window)
POS_RUN (positioner running)
RFG_RUN (ramp generator running)
RU_ACT (acceleration ramp active)
RD_ACT (deceleration ramp active)
Status of individual positioning ramp generator
Axis running in positive direction
Status of individual positioning ramp generator
Axis running in negative direction
POS_REST (residual distance present)
Basic positioner ramp function generator feedback
signal
SW_E_PLUS (software limit switch PLUS reached)
Function diagram 789b.8
Basic positioner ramp function generator feedback
signal
SW_E_MINUS (software limit switch MINUS reached)
Function diagram 789b.8
Basic positioner set setpoint control signal
ENABLE_POS_REF (enable basic positioner)
Function diagram 789a.7
14