Unit Parameter Commands And Queries - Comtech EF Data CDM-570A Installation And Operation Manual

70/140 mhz satellite modem; l-band satellite modem; reduced chassis depth l-band satellite modem
Hide thumbs Also See for CDM-570A:
Table of Contents

Advertisement

CDM-570A/570AL Satellite Modem with Optional Packet Processor
Serial-based Remote Product Management
8.3.4

Unit Parameter Commands and Queries

Command
Parameter
(Instruction
Type
Code and
Qualifier)
Compatible Mode
CMO=
1 byte, value of 0
or 1
Local/Remote
LRS=
1 byte,
Status
value of 0, 1 or 3
Front Panel
FPL=
1 byte,
Lockout
value of 0 or 1
Software Image
IMG=
1 byte,
value of 1 or 2
Circuit ID String
CID=
24 bytes
Arguments for
Command or
Response to
Query
Command or Query.
Sets or returns the CDM-570/CDM-570A compatible status in the form x, where:
0 = CDM-570 Compatible Mode
1 = CDM-570A Compatible Mode
Example: <0/CMO=1 (CDM-570A Compatible Mode)
Command or Query.
Sets or returns Local/Remote status in the form x, where:
0 = Local
1 = Serial Remote
3 = Ethernet Remote
Example: <0/LRS=1 (Serial Remote)
Command or Query.
Sets or returns the front panel lockout state in the form x, where:
0 = no lockout
1 = front panel lockout active
Disable the lockout by either FPL=0, or by setting into local mode using LRS=0
(response is LRS+ meaning FPL is disabled at the same time)
Note: When using the Optional Packet Processor Command Line Interface (CLI),
to verify CLI lockout:
<0/FPL?
>0/FPL=0 (Lockout disabled) or
>0/FPL=1 (Lockout enabled)
Command or Query.
Sets or returns Current Active software image in the form x, where:
1 = Bulk Image # 1 currently active
2 = Bulk Image # 2 currently active
Example: <0/IMG=1 (Image #1 active)
Command or Query.
Sets or returns the user-defined Circuit ID string.
Note: Circuit ID string is a fixed length of up to 24 characters. Valid characters
include: [Space] ( ) * + – , . / 0 thru 9 and A thru Z
Description of Arguments
8–23
MN-CDM570A
Revision 3
Query
Response to
(Instruction Code
Command
and Qualifier)
CMO=
CMO?
CMO=x
CMO?
(see Description of
CMO*
Arguments)
CMO#
LRS=
LRS?
LRS=x
LRS?
(see Description of
LRS*
Arguments)
LRS#
LRS+
FPL=
FPL?
FPL=x
FPL?
(see Description of
FPL*
Arguments)
FPL#
IMG=
IMG?
IMG=x
IMG?
(see Description of
IMG*
Arguments)
IMG#
CID=
CID?
CID=xxxxxxxxxxxxx
CID?
xxxxxxxxxxx
CID*
(see Description of
CID#
Arguments)
Response to
Query

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-570alCdmr-570al