Comtech EF Data CDM-570A Installation And Operation Manual page 293

70/140 mhz satellite modem; l-band satellite modem; reduced chassis depth l-band satellite modem
Hide thumbs Also See for CDM-570A:
Table of Contents

Advertisement

CDM-570A/570AL Satellite Modem with Optional Packet Processor
Serial-based Remote Product Management
Command
Parameter
(Instruction
Type
Code and
Qualifier)
CnC-APC
N/A
4 bytes
Frame Error
Rate
CnC-APC FER
AFR=
None
Reset
CnC-APC
APC=
1 byte, 0 thru 2
Activate/Suspend
CnC-APC State
N/A
2 bytes
Arguments for
Command or
Response to
Query
Query only.
Valid only in CDM-570A Compatible Mode (CMO=1).
Returns the value of CnC-APC FER in the form xE
x = value
E
= Exponent.
-c
Returns 9999 if modem is not in CnC-APC mode or if there is an APC frame sync
error.
Example: <0/AFE?
>0/AFE=8E-2
Command only.
Valid only in CDM-570A Compatible Mode (CMO=1).
This command takes no arguments.
Restarts CnC-APC FER measurement.
Command only.
Valid only in CDM-570A Compatible Mode (CMO=1).
Activates or suspends APC operation in the form x, where:
0 = no action
1 = Activate APC
2 = Suspend APC
Query only.
Valid only in CDM-570A Compatible Mode (CMO=1).
Returns the state of APC operation in form xx, where:
00 = APC is not active
01 = No Solution
02 = OK - ReBalance Done
03 = OK(Partial): CnC Ratio approaches limit
04 = OK(Partial): Local power approaches miminum value (-25 dBm for IF band)
05 = OK(Partial): Local power approaches minimum value (-40 dBm for L-Band)
06 = OK(Partial): Local power approaches maximum value (0 dBm)
07 = OK(Partial): Local power approaches limit set by max power level increase
08 = OK(Partial): Distant power approaches miminum value (-25 dBm for IF band)
09 = OK(Partial): Distant power approaches minimum value (-40 dBm for L-Band)
10 = OK(Partial): Distant power approaches maximum value (0 dBm)
11 = OK(Partial): Distant power approaches limit set by max power level increase
12 = OK(Partial): Incomplete
13 = No APC Frame Sync
14 = CnC Ratio Problem
15 = Local EbNo too high
16 = Distant EbNo too high
17 = Distant End ReBalance failed
Description of Arguments
, where:
-c
8–49
MN-CDM570A
Revision 3
Query
Response to
(Instruction Code
Command
and Qualifier)
N/A
AFE?
AFE= xE
Description of
Arguments)
AFR=
N/A
N/A
APC=
N/A
N/A
N/A
APS?
APS=xx
(see Description of
Arguments)
Response to
Query
(see
- c

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-570alCdmr-570al

Table of Contents