CDM-570A/570AL Satellite Modem with Optional Packet Processor
Serial-based Remote Product Management
Command
Parameter
(Instruction
Type
Code and
Qualifier)
Force 1:1 Switch
FSW=
None
Outdoor Unit
ODU=
1 byte,
Comms Enable
value of 0 or 1
IP Address
IPA=
18 bytes,
numerical
IP Gateway
IPG=
15 bytes
numerical
MAC Address
N/A
12 bytes,
Alphanumerical
Arguments for
Command or
Response to
Query
Command only.
This command takes no arguments.
Forces the unit to toggle the Unit Fail relay to the 'fail' state for approximately
500ms. If the unit is part of a 1:1 pair and it is currently the 'On Line' unit, this
forces a switchover, so the unit is then be in 'Standby' mode.
Notes:
1) The 1:1 redundancy system must be installed.
2) Both online and offline units must be in Manual Mode for this command to
function.
3) If the 1:1 redundancy system is not installed, or the unit is offline, then the
command returns FSW?
Command or Query – CDM-570A Only.
Enables or disables communications, via the FSK link, with a Comtech EF Data
transceiver (ODU) in the form x, where:
0 = Disabled
1 = Enabled
Example: <0/ODU=0 (ODU disabled)
Command or Query.
Sets or returns the IP address and network prefix for the '10/100 M&C' 10/100
BaseT Ethernet management port, in the form xx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address
yy is the network prefix (from 8 to 30)
Example: <0/IPA=010.006.030.001.24
Command or Query.
Sets or returns the IP Gateway Address for the Ethernet management port, in the
form aaa.bbb.ccc.ddd, where permitted ranges (all zeroes are not permitted) are:
aaa = 0–223
bbb = 0–255
ccc = 0–255
ddd = 0–255
Example: <0/IPG=010.006.030.001
Query only.
Returns the unique MAC Address for the modem.
Example: <0/MAC?
>0/MAC=0006B00001C2
Description of Arguments
8–29
MN-CDM570A
Revision 3
Query
Response to
(Instruction Code
Command
and Qualifier)
FSW= (message
N/A
N/A
OK)
ODU=
ODU?
ODU=x
ODU?
(see Description of
ODU*
Arguments)
ODU#
IPA=
IPA?
IPA=
IPA?
xxx.xxx.xxx.xxx.yy
IPA*
(see Description of
IPA#
Arguments)
IPG=
IPG?
IPG=
IPG?
xxx.xxx.xxx.xxx
IPG*
(see Description of
IPG#
Arguments)
N/A
MAC?
MAC=aabbccddeeff
(see Description of
Arguments)
Response to
Query