fddi port lerCutoff
3500
9000
9400
3900
9300
Sets the link error rate estimate at which a link connection is disabled.
When the lerCutoff value is reached, the PHY that detected a problem is
disabled.
Valid Minimum Abbreviation
fd po lerC
Important Considerations
The lerCutoff value must be lower than the lerAlarm value so that the
network management software is alerted to a problem before the PHY
(port) is actually removed from the network.
Set the lerCutoff below these values so that a port is removed only as
a last resort. The SMT Standard recommended value is 7.
The lerCutoff value is expressed as an exponent (such as 1 x 10
healthy network has an LER exponent between 1 x 10
You can use this command to configure the same setting on multiple
ports simultaneously. When you specify multiple port numbers, the
system prompts you to choose the setting and then applies it to all of
the ports.
Options
Prompt
Description
Ports
One or more FDDI station ports
for which you want to set the
port lerCutoff
lerCutoff
Link error rate estimate at
which a link connection is
disabled
fddi port lerCutoff
-10
and 1 x 10
Possible Values
[Default]
Any of the
–
available ports
on the installed
FDDI modules
all
4 – 15
4
243
-10
). A
-15
.