C
7: E
206
HAPTER
THERNET
P
ORTS
Field
rxFrames
slot:channel
(9000 switch fabric
module)
slot:port
(9000)
txBytes
txErrs
txFrames
txQOverflows
vendorName
(3500)
To display Ethernet port statistics relative to a baseline, see the
Implementation Guide for your system.
Procedure
1 To display summary information about Ethernet ports, enter:
ethernet summary
2 At the prompt (for example,
information you want to display, or to display a port summary, specify
Indicate a range of ports with a hyphen (-). Separate nonconsecutive
ports with a comma.
The system displays port information based on the ports that you
specified.
Description
Number of frames that were copied into receive buffers
by this port.
®
Maps a CoreBuilder
9000 switch fabric module port to
an interface module backplane link. The "channel"
designation is just a backplane trace number. For
example, to troubleshoot a problem with switch fabric
module port 5 (slot:channel 3:1), look at the first
backplane link for slot 3.
Module slot and port number in the CoreBuilder 9000
system.
Number of bytes that were transmitted by this port,
including framing characters.
Sum of all transmit errors that are associated with this
port (summary report only).
Number of frames that were transmitted by this port.
Number of frames that were lost because transmit queue
was full.
Vendor name for a GBIC module. Other modules display
n/a.
), select the ports whose
(1-24|all|?)
?