Dc100 Service Entry - Xerox DocuColor 1632 Service Manual

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

Table 1 dC Routines
dC Number
Name
371
Configuration Page
612
Color Test Pattern Print
685
Regicon
921
ATC Calibration
922
TRC Control/Toner Density
Adjustment
924
TRC Adjustment
934
ADC/AGC Setup
945
IIT calibration
956
Belt Edge Learn
General Procedures and Information
DC Quick, dC100
Description
Allows viewing of current software version
and Market Place setting, Machine Con-
figuration, Output Device(s), Accessories,
Tray 1 Paper Size setting, Feature Con-
fig., and Input Device.
These settings can be changed to align
with the machine configuration.
1.
Outputs a test pattern to identify a
copy quality problem.
2.
Generates a test pattern from the
Pattern Generator in the machine.
Color Registration/Skew setup
Enter ATC Sensor Calibration code into
NVM.
Measure the grayscale patch by the ADC
sensor. Make the LUT for IOT TRC cor-
rection.
Manually fine adjust each color (low/mid/
high density) in PG.
Execute automatic adjustment of the ADC
Sensor Gain.
1.
Calculate and set the white reference
compensation coefficient.
2.
Correct the IIT sensitivity variation.
Set up the Belt Edge Sensor.

dC100 Service Entry

When entering Diagnostics, this routine allows you to view faults in progress, Non-Zero Jams
and HFSI items requiring replacement. Service entry allows you to view product information,
such as:
ï
Product Code
ï
Machine Serial Number
ï
Total Copies
ï
Copies since Last Call
ï
IOT Software Version
Procedure
1.
Enter the Diagnostic Mode. Refer to
2.
Check the HFSI Requiring Replacement.
3.
Check the Non-Zero Jams. Jams that have occurred since the last service exit with the
Complete Closeout option selected. Check for any Jams that have a high number of
occurrences.
4.
Check the Faults In Progress. If any faults in progress are displayed, troubleshoot
accordingly.
5.
Select the Refresh button to have the PWS request and receive the latest information on
Total Copies, Copies Since Last Call, Non-Zero Jams or HFSI Requiring Replacement.
6/02
6-6
Entering Diagnostic Mode using the
PWS.
Prelaunch Training/Review
DC1632/2240

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 2240

Table of Contents