Parameter
Hotline Dial Tone Duration
CLI: hotline-dia-ltone-duration
[TargetOfChannel_HotLineTo
neDuration]
27.6

Configuring Caller Display Information

The Caller Display Information table lets you configure caller identification strings (Caller
ID) per FXS and FXO port. this table also lets you enable the device to send the Caller ID
to the IP when a call is made. The called party can use this information for caller
identification. The device sends the configured caller ID in the outgoing INVITE message's
From header. For information on Caller ID restriction according to destination/source
prefixes, see ''Configuring Source/Destination Number Manipulation'' on page 359.
Notes:
If an FXS port receives 'private' or 'anonymous' strings in the SIP From header,
the calling name or number is not sent to the Caller ID display.
If the device detects Caller ID on an FXO line (EnableCallerID = 1), it uses this
Caller ID instead of the Caller ID configured in the Caller Display Information table.
The following procedure describes how to configure caller ID in the Web interface. You can
also configure this using the table ini file parameter, CallerDisplayInfo or CLI command,
configure voip > gw analoggw caller-display-info.
To configure Caller display:
1.
Open the Caller Display Information page (Configuration tab > VoIP menu > GW and
IP to IP > Analog Gateway > Caller Display Information).
2.
Click Add; the following dialog box appears:
Version 6.8
field is automatically dialed if the following occurs:
FXS interfaces: The phone is off-hooked
FXO interfaces: A ring signal (from a PBX/PSTN switch) is
detected on the FXO line. The device initiates a call to the
destination without seizing the FXO line. The line is seized
only after the SIP call is answered.
[2] Hotline = Automatic dialing is done after an interval
configured by the 'Hotline Dial Tone Duration' parameter:
FXS interfaces: When the phone is off-hooked and no digit
is dialed within a user-defined time, the configured
destination number is automatically dialed.
FXO interfaces: If a ring signal is detected, the device
seizes the FXO line, plays a dial tone, and then waits for
DTMF digits. If no digits are detected within a user-defined
time, the configured destination number is automatically
dialed by sending a SIP INVITE message with this number.
Defines the duration (in seconds) after which the destination phone
number is automatically dialed. This is applicable only if the port
has been configured for Hotline (i.e., 'Auto Dial Status' is set to
Hotline).
The valid value is 0 to 60. The default is 16.
Note: You can configure this Hotline interval for all ports, using the
global parameter, HotLineToneDuration.