Parameter
Proxy Set Table
Web: Proxy Set Table
EMS: Proxy Set
CLI: configure voip > voip-network
proxy-set
[ProxySet]
Registrar Parameters
Web: Enable Registration
EMS: Is Register Needed
CLI: enable-registration
[IsRegisterNeeded]
Web/EMS: Registrar Name
CLI: registrar-name
[RegistrarName]
Web: Registrar IP Address
EMS: Registrar IP
CLI: ip-addrr-rgstrr
[RegistrarIP]
User's Manual
For a description of this table, see ''Configuring Proxy Sets'' on
page 272.
To configure the Proxy Set attributes (such as Proxy Load
Balancing) in the ini file, use the ProxySet parameter.
This table parameter defines the Proxy Set ID table. This
includes, for example, Proxy keep-alive and load balancing and
redundancy mechanisms.
The format of the ini file table parameter is as follows:
[ ProxySet ]
FORMAT ProxySet_Index = ProxySet_ProxyName,
ProxySet_EnableProxyKeepAlive,
ProxySet_ProxyKeepAliveTime,
ProxySet_ProxyLoadBalancingMethod,
ProxySet_IsProxyHotSwap, ProxySet_SRD,
ProxySet_ClassificationInput,
ProxySet_ProxyRedundancyMode,
ProxySet_DNSResolveMethod,
ProxySet_KeepAliveFailureResp;
[ \ProxySet ]
For a description of this table, see ''Configuring Proxy Sets'' on
page 272.
For configuring the IP addresses per Proxy Set in the ini file,
use the ProxyIP parameter.
Enables the device to register to a Proxy/Registrar server.
[0] Disable = (Default) The device doesn't register to
Proxy/Registrar server.
[1] Enable = The device registers to Proxy/Registrar server
when the device is powered up and at every user-defined
interval (configured by the parameter RegistrationTime).
Notes:
This parameter is applicable only to the Gateway
application.
The device sends a REGISTER request for each channel or
for the entire device (according to the AuthenticationMode
parameter).
Defines the Registrar domain name. If specified, the name is
used as the Request-URI in REGISTER messages. If it isn't
specified (default), the Registrar IP address, or Proxy name or
IP address is used instead.
The valid range is up to 100 characters.
Note: This parameter is applicable only to the Gateway
application.
Defines the IP address (or FQDN) and port number (optional)
of the Registrar server. The IP address is in dotted-decimal
notation, e.g., 201.10.8.1:<5080>.
Notes:
This parameter is applicable only to the Gateway
application.
764