AudioCodes Mediant 1000B User Manual page 836

Analog & digital voip media gateway enterprise session border controller gateway & e-sbc
Hide thumbs Also See for Mediant 1000B:
Table of Contents

Advertisement

Parameter
EMS: SIP Endpoints > Call
Waiting
CLI: configure voip > gw
analoggw call-waiting
[CallWaitingPerPort]
Web: Number of Call Waiting
Indications
EMS: Call Waiting Number of
Indications
CLI: nb-of-cw-ind
[NumberOfWaitingIndications]
Web: Time Between Call Waiting
Indications
EMS: Call Waiting Time Between
Indications
CLI: time-between-cw
[TimeBetweenWaitingIndications]
Web/EMS: Time Before Waiting
Indications
CLI: time-b4-cw-ind
[TimeBeforeWaitingIndications]
Web/EMS: Waiting Beep
Duration
CLI: waiting-beep-dur
[WaitingBeepDuration]
EMS: First Call Waiting Tone ID
[FirstCallWaitingToneID]
User's Manual
format of this The format of the ini file table parameter format of
the ini file table parameter is as follows:
[CallWaitingPerPort]
FORMAT CallWaitingPerPort_Index =
CallWaitingPerPort_IsEnabled, CallWaitingPerPort_Module,
CallWaitingPerPort_Port;
[\CallWaitingPerPort]
For example:
CallWaitingPerPort 0 = 0,1,1; (call waiting disabled for Port 1 of
Module 1)
CallWaitingPerPort 1 = 1,1,2; (call waiting enabled for Port 2 of
Module 1)
Notes:
This parameter is applicable only to FXS ports.
For a detailed description of this table, see Configuring Call
Waiting on page 467.
Defines the number of call waiting indications that are played to
the called telephone that is connected to the device for Call
Waiting.
The valid range is 1 to 100 indications. The default is 2.
Note: This parameter is applicable only to FXS ports.
Defines the time (in seconds) between consecutive call waiting
indications for call waiting.
The valid range is 1 to 100. The default is 10.
Note: This parameter is applicable only to FXS ports.
Defines the interval (in seconds) before a call waiting indication is
played to the port that is currently in a call.
The valid range is 0 to 100. The default time is 0 seconds.
Note: This parameter is applicable only to FXS ports.
Defines the duration (in msec) of call waiting indications that are
played to the port that is receiving the call.
The valid range is 100 to 65535. The default is 300.
Note: This parameter is applicable only to FXS ports.
Defines the index of the first Call Waiting Tone in the CPT file.
This feature enables the called party to distinguish between
different call origins (e.g., external versus internal calls).
There are three ways to use the distinctive call waiting tones:
Playing the call waiting tone according to the SIP Alert-Info
header in the received 180 Ringing SIP response. The value of
the Alert-Info header is added to the value of the
FirstCallWaitingToneID parameter.
Playing the call waiting tone according to PriorityIndex in the
ToneIndex table parameter.
Playing the call waiting tone according to the parameter
"CallWaitingTone#' of a SIP INFO message.
The device plays the tone received in the 'play tone
CallWaitingTone#' parameter of an INFO message plus the value
of this parameter minus 1.
836
Mediant 1000B Gateway & SBC
Description
Document #: LTRT-27034

Advertisement

Table of Contents
loading

Table of Contents