Parameter
[FwdInfo]
Call Forward Reminder Ring Parameters
Notes:
These parameters are applicable only to FXS interfaces.
For a description of this feature, see Call Forward Reminder Ring on page 419.
Web/EMS: Enable NRT
Subscription
CLI: nrt-subscription
[EnableNRTSubscription]
Web: AS Subscribe
IPGroupID
CLI: as-subs-ipgroupid
[ASSubscribeIPGroupID]
Web: NRT Retry
Subscription Time
EMS: NRT Subscription
Retry Time
[NRTSubscribeRetryTime]
Web/EMS: Call Forward
Ring Tone ID
CLI: cfe-ring-tone-id
[CallForwardRingToneID]
51.10.5.4

Message Waiting Indication Parameters

The message waiting indication (MWI) parameters are described in the table below.
Parameter
Web: Enable MWI
EMS: MWI Enable
CLI: enable-mwi
[EnableMWI]
User's Manual
[\FwdInfo]
Where,
Module = Module number, where 1 denotes the module in Slot 1.
Port = Port number, where 1 denotes Port 1 of a module.
For example:
Below configuration forwards calls originally destined to Port 1 of
Module 1 to "1001" upon On Busy:
FwdInfo 0 = 1,1001,30,1,1;
Below configuration forwards calls originally destined to Port 2 of
Module 1 to an IP address upon On Busy:
FwdInfo 1 = 1,2003@10.5.1.1,30,1,2;
For a detailed description of this table, see Configuring Call Forward on
page 464.
Note: The indexing of this parameter starts at 0.
Enables endpoint subscription for Ring reminder event notification
feature.
[0] Disable (default)
[1] Enable
Defines the IP Group ID that contains the Application server for
Subscription.
The valid value range is 1 to 8. The default is -1 (i.e., not configured).
Defines the Retry period (in seconds) for Dialog subscription if a previous
request failed.
The valid value range is 10 to 7200. The default is 120.
Defines the ringing tone type played when call forward notification is
accepted.
The valid value range is 1 to 5. The default is 1.
Table 51-45: MWI Parameters
Enables Message Waiting Indication (MWI).
[0] Disable (default).
[1] Enable
Notes:
This parameter is applicable only to FXS interfaces.
The device supports only the receipt of SIP MWI NOTIFY