Parameter
Web: AMD Sensitivity Level
CLI: amd-sensitivity-level
[IpProfile_AMDSensitivityLevel]
Web: AMD Max Greeting Time
CLI: amd-max-greeting-time
[IpProfile_AMDMaxGreetingTim
e]
Web: AMD Max Post Silence
Greeting Time
CLI: amd-max-post-silence-
greeting-time
[IpProfile_AMDMaxPostSilence
GreetingTime]
Web: AMD Mode
CLI: amd-mode
[IpProfile_AmdMode]
Web: QSIG Tunneling
CLI: enable-qsig-tunneling
[IpProfile_EnableQSIGTunnelin
g]
Version 6.8
Sensitivity Level' parameter.
For more information on the AMD feature, see 'Answering
Machine Detection (AMD)' on page 175.
The corresponding global parameter is
AMDSensitivityParameterSuit.
Defines the AMD detection sensitivity level of the selected AMD
Parameter Suite (using the 'AMD Sensitivity Parameter Suite'
parameter).
For Parameter Suite 0, the valid range is 0 to 7, where 0 is for best
detection of an answering machine and 7 for best detection of a
live call. For any Parameter Suite other than 0, the valid range is 0
to 15, where 0 is for best detection of an answering machine and
15 for best detection of a live call.
Note: The corresponding global parameter is AMDSensitivityLevel.
Defines the maximum duration (in 5-msec units) that the device
can take to detect a greeting message.
The valid range value is 0 to 511. The default is 300.
Note: The corresponding global parameter is
AMDMaxGreetingTime.
Defines the maximum duration of silence from after the greeting
time is over (configured by AMDMaxGreetingTime) until the
device's AMD decision.
Note: The corresponding global parameter is
AMDMaxPostGreetingSilenceTime.
Enables the device to disconnect the IP-to-Tel call upon detection
of an answering machine on the Tel side.
[0] Don't Disconnect = (Default) Device does not disconnect call
upon detection of an answering machine.
[1] Disconnect on AMD = Device disconnects call upon
detection of an answering machine. It disconnects the call only
after receipt of an ISDN Connect from the Tel side. In such a
scenario, the device sends a SIP BYE message upon AMD
Notes:
This feature (when set to [1]) cannot work together when the
EnableEarlyAMD parameter is set to [1].
This feature does not need the receipt of the SIP X-Detect
header in the incoming INVITE to activate the AMD.
The corresponding global parameter is AMDmode.
Enables QSIG tunneling-over-SIP for this SIP entity. This is
according to IETF Internet-Draft draft-elwell-sipping-qsig-tunnel-03
and ECMA-355 and ETSI TS 102 345.
[0] Disable (default).
[1] Enable = Enables QSIG tunneling from QSIG to SIP, and
vice versa. All QSIG messages are sent as raw data in
corresponding SIP messages using a dedicated message body.
Notes:
QSIG tunneling must be enabled on originating and terminating
devices.
To enable this function, set the ISDNDuplicateQ931BuffMode