Parameter
Message Policy Table
Web: Message Policy Table
CLI: configure voip > sbc
message-policy
[MessagePolicy]
51.8

Coders and Profile Parameters

The profile parameters are described in the table below.
Parameter
Coders Table / Coder Groups Table
Web: Coders Table/Coder
Group Settings
EMS: Coders Group
CLI: configure voip >
coders-and-profiles
coders-group
[CodersGroup0]
[CodersGroup1]
[CodersGroup2]
[CodersGroup3]
[CodersGroup4]
[CodersGroup5]
[CodersGroup6]
[CodersGroup7]
[CodersGroup8]
[CodersGroup9]
User's Manual
This table parameter configures SIP message policy rules for blocking
(blacklist) unwanted incoming SIP messages or allowing (whitelist)
receipt of desired messages.
The format of the ini file table parameter is as follows:
[MessagePolicy]
FORMAT MessagePolicy_Index = MessagePolicy_Policy,
MessagePolicy_MaxMessageLength,
MessagePolicy_MaxHeaderLength, MessagePoliy_MaxBodyLength,
MessagePolicy_MaxNumHeaders, MessagePolicy_MaxNumBodies,
MessagePolicy_SendRejection, MessagePolicy_MethodListType,
MessagePolicy_MethodList, MessagePolicy_BodyListType,
MessagePolicy_BodyList;
[/MessagePolicy]
For a detailed description of this table, see Configuring SIP Message
Policy Rules.
Table 51-33: Profile Parameters
This table parameter defines the device's coders. Each group can consist
of up to 10 coders. The first Coder Group is the default coder list and the
default Coder Group.
The format of the ini file table parameter is as follows:
[ CodersGroup<0-9> ]
FORMAT CodersGroup0_Index = CodersGroup0_Name,
CodersGroup0_pTime, CodersGroup0_rate,
CodersGroup0_PayloadType, CodersGroup0_Sce;
[ \CodersGroup<0-9 ]
For example, below are defined two Coder Groups (0 and 1):
[ CodersGroup0 ]
FORMAT CodersGroup0_Index = CodersGroup0_Name,
CodersGroup0_pTime, CodersGroup0_rate,
CodersGroup0_PayloadType, CodersGroup0_Sce;
CodersGroup0 0 = g711Alaw64k, 20, 0, 255, 0;
CodersGroup0 1 = eg711Ulaw, 10, 0, 71, 0;
CodersGroup0 2 = eg711Ulaw, 10, 0, 71, 0;
[ \CodersGroup0 ]
[ CodersGroup1 ]
FORMAT CodersGroup1_Index = CodersGroup1_Name,
CodersGroup1_pTime, CodersGroup1_rate,
CodersGroup1_PayloadType, CodersGroup1_Sce;
CodersGroup1 0 = Transparent, 20, 0, 56, 0;
CodersGroup1 1 = g726, 20, 0, 23, 0;
[ \CodersGroup1 ]