Parameter
Web: Web and Telnet
Access List Table
EMS: Web Access
Addresses
[WebAccessList_x]

51.1.2 Web Parameters

The Web parameters are described in the table below.
Parameter
Web: Enable web access from all
interfaces
CLI: web-access-from-all-
interfaces
[EnableWebAccessFromAllInterfac
es]
Web: Password Change Interval
[WebUserPassChangeInterval]
Web: User Inactivity Timer
[UserInactivityTimer]
Web: Session Timeout
[WebSessionTimeout]
User's Manual
This table configures up to ten IP addresses that are permitted to
access the device's Web interface and Telnet interfaces. Access from
an undefined IP address is denied. When no IP addresses are defined
in this table, this security feature is inactive (i.e., the device can be
accessed from any IP address).
The default is 0.0.0.0 (i.e., the device can be accessed from any IP
address).
For example:
WebAccessList_0 = 10.13.2.66
WebAccessList_1 = 10.13.77.7
For a description of this parameter, see ''Configuring Web and Telnet
Access List'' on page 64.
Table 51-2: Web Parameters
Enables Web access from any of the device's IP network
interfaces. This feature applies to HTTP and HTTPS protocols.
[0] = (Default) Disable – Web access is only through the
OAMP interface.
[1] = Enable - Web access is through any network interface.
Defines the duration (in minutes) of the validity of Web login
passwords. When this duration expires, the password of the
Web user must be changed.
The valid value is 0 to 100000, where 0 means that the
password is always valid. The default is 1140.
Note: This parameter is applicable only when using the Web
Users table, where the default value of the 'Password Age'
parameter in the Web Users table inherits this parameter's
value.
Defines the duration (in days) for which a user has not logged in
to the Web interface, after which the status of the user becomes
inactive and can no longer access the Web interface. These
users can only log in to the Web interface if their status is
changed (to New or Valid) by a System Administrator or Master
user.
The valid value is 0 to 10000, where 0 means inactive. The
default is 90.
Note: This parameter is applicable only when using the Web
Users table.
Defines the duration (in minutes) of Web inactivity of a logged-in
user, after which the user is automatically logged off the Web
interface.
The valid value is 0-100000, where 0 means no timeout. The
default is 15.
Note: This parameter can apply to all users, or per user when
716
Mediant 1000B Gateway & SBC
Description
Description
Document #: LTRT-27034