[NUMBER OF CALL PROGRESS TONES]: Contains the following key:
'Number of Call Progress Tones' defining the number of Call Progress Tones that are
defined in the file.
[CALL PROGRESS TONE #X]: containing the Xth tone definition, starting from 0 and
not exceeding the number of Call Progress Tones less 1 defined in the first section
(e.g., if 10 tones, then it is 0 to 9), using the following keys:
Tone Type: Call Progress Tone types:
Tone Modulation Type: Amplitude Modulated (1) or regular (0)
Tone Form: The tone's format can be one of the following:
Low Freq [Hz]: Frequency (in Hz) of the lower tone component in case of dual
frequency tone, or the frequency of the tone in case of single tone. This is not
relevant to AM tones.
High Freq [Hz: Frequency (in Hz) of the higher tone component in case of dual
frequency tone, or zero (0) in case of single tone (not relevant to AM tones).
Low Freq Level [-dBm]: Generation level 0 dBm to -31 dBm in dBm (not
relevant to AM tones).
High Freq Level: Generation level of 0 to -31 dBm. The value should be set to
32 in the case of a single tone (not relevant to AM tones).
First Signal On Time [10 msec]: 'Signal On' period (in 10 msec units) for the
first cadence on-off cycle. For continuous tones, this parameter defines the
detection period. For burst tones, it defines the tone's duration.
First Signal Off Time [10 msec]: 'Signal Off' period (in 10 msec units) for the
first cadence on-off cycle (for cadence tones). For burst tones, this parameter
defines the off time required after the burst tone ends and the tone detection is
reported. For continuous tones, this parameter is ignored.
Second Signal On Time [10 msec]: 'Signal On' period (in 10 msec units) for the
second cadence on-off cycle. Can be omitted if there isn't a second cadence.
Second Signal Off Time [10 msec]: 'Signal Off' period (in 10 msec units) for the
second cadence on-off cycle. Can be omitted if there isn't a second cadence.
Third Signal On Time [10 msec]: 'Signal On' period (in 10 msec units) for the
third cadence on-off cycle. Can be omitted if there isn't a third cadence.
Third Signal Off Time [10 msec]: 'Signal Off' period (in 10 msec units) for the
third cadence on-off cycle. Can be omitted if there isn't a third cadence.
User's Manual
[1] Dial Tone
[2] Ringback Tone
[3] Busy Tone
[4] Congestion Tone
[6] Warning Tone
[7] Reorder Tone
[8] Confirmation Tone
[9] Call Waiting Tone - heard by the called party
[15] Stutter Dial Tone
[16] Off Hook Warning Tone
[17] Call Waiting Ringback Tone - heard by the calling party
[18] Comfort Tone
[23] Hold Tone
[46] Beep Tone
Continuous (1)
Cadence (2)
Burst (3)