27.2

Configuring Metering Tones

The FXS interfaces can generate 12/16 KHz metering pulses toward the Tel side (e.g., for
connection to a pay phone or private meter). Tariff pulse rate is determined according to
the device's Charge Codes table. This capability enables users to define different tariffs
according to the source/destination numbers and the time-of-day. The tariff rate includes
the time interval between the generated pulses and the number of pulses generated on
answer.
Notes:
The Metering Tones page is available only for FXS interfaces.
Charge Code rules can be assigned to routing rules in the Outbound IP Routing
table (see ''Configuring Outbound IP Routing Table'' on page 383). When a new
call is established, the Outbound IP Routing table is searched for the destination
IP address. Once a route is located, the Charge Code (configured for that route) is
used to associate the route with an entry in the Charge Codes table.
To configure Metering tones:
1.
Open the Metering Tones page (Configuration tab > VoIP menu > GW and IP to IP >
Analog Gateway > Metering Tones).
2.
Configure the Metering tones parameters as required. For a description of the
parameters appearing on this page, see ''Configuration Parameters Reference'' on
page 715.
3.
Click Submit.
4.
To save the changes to the flash memory, see ''Saving Configuration'' on page 568.
If you set the 'Generate Metering Tones' parameter to Internal Table, access the Charge
Codes Table page by clicking the Charge Codes Table
on configuring the Charge Codes table, see ''Configuring Charge Codes'' on page 454.
27.3

Configuring FXO Settings

The FXO Settings page allows you to configure the device's specific FXO parameters. For
a description of these parameters, see ''Configuration Parameters Reference'' on page
715.
Note:
Version 6.8
Figure 27-2: Metering Tones Page
The FXO Settings page is available only for FXO interfaces.
459