Identifying Audiocodes Syslog Messages Using Facility Levels; Syslog Fields For Answering Machine Detection (Amd) - AudioCodes Mediant 1000B User Manual

Analog & digital voip media gateway enterprise session border controller gateway & e-sbc
Hide thumbs Also See for Mediant 1000B:
Table of Contents

Advertisement

Error Abbreviation
AL
AO
AP
AR

45.1.2 Identifying AudioCodes Syslog Messages using Facility Levels

The device's Syslog messages can easily be identified and distinguished from Syslog
messages from other equipment, by setting its Facility level. The Facility levels of the
device's Syslog messages are numerically coded with decimal values. Facility level may
use any of the "local use" facilities (0 through 7), according to RFC 3164. Implementing
Facility levels is useful, for example, if you collect the device's as well as other equipments'
Syslog messages on the same server. Therefore, in addition to filtering Syslog messages
according to IP address, the messages can be filtered according to Facility level.
The Facility level is configured using the SyslogFacility ini file parameter, which provides
the following options:
Numerical Value
16 (default)
17
18
19
20
21
22
23
Syslog messages begin with a less-than ("<") character, followed by a number, which is
followed by a greater-than (">") character. This is optionally followed by a single ASCII
space. The number is known as the Priority and represents both the Facility level and the
Severity level. A Syslog message with Facility level 16 is shown below:
Facility: LOCAL0 - reserved for local use (16)

45.1.3 Syslog Fields for Answering Machine Detection (AMD)

The Syslog message can include information relating to the Answering Machine Detection
(AMD) feature. AMD is used to detect whether a human (including a fax machine), an
answering machine, silence, or answering machine beeps have answered the call on the
remote side. This feature is applicable only to the Gateway application.
AMDSignal – this field can acquire one of the following values:
voice (V)
answer machine (A)
silence (S)
unknown (U)
User's Manual
Invalid Header Length
Invalid Codec Type
Unknown Aggregation Payload Type
Invalid Routing Flag Received
Table 45-3: Syslog Facility Levels
local use 0 (local0)
local use 1 (local1)
local use 2 (local2)
local use 3 (local3)
local use 4 (local4)
local use 5 (local5)
local use 6 (local6)
local use 7 (local7)
680
Mediant 1000B Gateway & SBC
Error Name Description
Facility Level
Document #: LTRT-27034