Parameter
[LifeLineType]
Web: Delay After Reset [sec]
CLI: delay-after-reset
[GWAppDelayTime]
[Mediant1000DualPowerSupply
Supported]
Version 6.8
Test succeeds: The problem is due to a logical link failure (i.e.,
Ethernet cable disconnected on the remote switch) and the
following mechanisms are activated if enabled:
Busy Out (see the EnableBusyOut parameter)
Lifeline (see the LifeLineType parameter)
Test fails: The device resets (if this parameter is set to [2]) to
overcome the internal communication error.
Notes:
For this parameter to take effect, a device reset is required.
LAN watchdog is applicable only if the Ethernet connection is
full duplex.
Defines the condition(s) upon which the Lifeline analog (FXS)
feature is activated. The Lifeline feature can be activated upon a
power outage or network failure (i.e., loss of IP connectivity). Upon
any of these conditions, the Lifeline feature provides PSTN
connectivity and thus call continuity for the FXS phone users.
If the device is in Lifeline mode and the scenario that caused it to
enter Lifeline (e.g., power outage) no longer exists (e.g., power
returns), the device exists Lifeline and operates as normal.
[0] = (Default) Lifeline is activated upon power outage.
[1] = Lifeline is activated upon power outage.
[2] = Lifeline is activated upon a power outage network failure
(logical link disconnection), or when the Trunk Group is in Busy
Out state (see the EnableBusyOut parameter).
The Lifeline (FXS) phone is connected to the following port:
FXS Port 1 of each FXS module
FXS Port 1 connects to the POTS (Lifeline) phone as well as to the
PSTN / PBX, using a splitter cable.
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
To enable Lifeline upon network failure, the LAN Watchdog
feature must be activated (see the EnableLANWatchDog
parameter).
A Lifeline phone connection can be set up for each installed
FXS module (using Port I).
For information on Lifeline cabling, refer to the Installation
Manual.
Defines the time interval (in seconds) that the device's operation is
delayed after a reset.
The valid range is 0 to 45. The default is 7 seconds.
Note: This feature helps overcome connection problems caused by
some LAN routers or IP configuration parameters' modifications by
a DHCP server.
Enables the device to send an alarm (to the SNMP client and Web
interface) if one of the Power Supply modules is removed from the
chassis or not operating correctly (failure).
[1] = (Default) Disable - no alarm is sent.
[2] = Enable - an alarm is sent.
739