AudioCodes Mediant 1000B User Manual page 84

Analog & digital voip media gateway enterprise session border controller gateway & e-sbc
Hide thumbs Also See for Mediant 1000B:
Table of Contents

Advertisement

configured.
The first word of the Format line must be "FORMAT", followed by the Index field
name and then an equal "=" sign. After the equal sign, the names of the columns
are listed.
Columns must be separated by a comma ",".
The Format line must only include columns that can be modified (i.e., parameters
that are not specified as read-only). An exception is Index fields, which are
mandatory.
The Format line must end with a semicolon ";".
Data line(s): Contain the actual values of the columns (parameters). The values are
interpreted according to the Format line.
The first word of the Data line must be the table's string name followed by the
Index field.
Columns must be separated by a comma ",".
A Data line must end with a semicolon ";".
End-of-Table Mark: Indicates the end of the table. The same string used for the
table's title, preceded by a backslash "\", e.g., [\MY_TABLE_NAME].
The following displays an example of the structure of a table ini file parameter.
[Table_Title]
; This is the title of the table.
FORMAT Index = Column_Name1, Column_Name2, Column_Name3;
; This is the Format line.
Index 0 = value1, value2, value3;
Index 1 = value1, $$, value3;
; These are the Data lines.
[\Table_Title]
; This is the end-of-the-table-mark.
The table ini file parameter formatting rules are listed below:
Indices (in both the Format and the Data lines) must appear in the same order. The
Index field must never be omitted.
The Format line can include a subset of the configurable fields in a table. In this case,
all other fields are assigned with the pre-defined default values for each configured
line.
The order of the fields in the Format line isn't significant (as opposed to the Index
fields). The fields in the Data lines are interpreted according to the order specified in
the Format line.
The double dollar sign ($$) in a Data line indicates the default value for the parameter.
The order of the Data lines is insignificant.
Data lines must match the Format line, i.e., it must contain exactly the same number
of Indices and Data fields and must be in exactly the same order.
A row in a table is identified by its table name and Index field. Each such row may
appear only once in the ini file.
Table dependencies: Certain tables may depend on other tables. For example, one
table may include a field that specifies an entry in another table. This method is used
to specify additional attributes of an entity, or to specify that a given entity is part of a
larger entity. The tables must appear in the order of their dependency (i.e., if Table X
is referred to by Table Y, Table X must appear in the ini file before Table Y).
For general ini file formatting rules, see ''General ini File Formatting Rules'' on page 85.
The table below displays an example of a table ini file parameter:
[ CodersGroup0 ]
FORMAT CodersGroup0_Index = CodersGroup0_Name, CodersGroup0_pTime,
CodersGroup0_rate, CodersGroup0_PayloadType, CodersGroup0_Sce;
User's Manual
Mediant 1000B Gateway & SBC
84
Document #: LTRT-27034

Advertisement

Table of Contents
loading

Table of Contents