Isdn Bri Parameters - AudioCodes Mediant 1000B User Manual

Analog & digital voip media gateway enterprise session border controller gateway & e-sbc
Hide thumbs Also See for Mediant 1000B:
Table of Contents

Advertisement

Parameter
Form
CLI: NTT-DID-signaling-
form
[NTTDIDSignallingForm]
EMS: Enable DID
[EnableDID]
CLI: wink-time
[WinkTime]
51.10.5.13

ISDN BRI Parameters

The automatic dialing upon off-hook parameters are described in the table below.
Parameter
BRI-to-SIP Supplementary Services Codes for Call Forward
Note: Upon receipt of an ISDN Facility message for call forward from the BRI phone, the device
sends a SIP INVITE to the softswitch with a user-defined code in the SIP To header, representing the
reason for the call forward. For more information on BRI call forwarding, see ''BRI Call Forwarding'' on
page 420.
Web/EMS: Call Forward
Unconditional
[SuppServCodeCFU]
User's Manual
DTMF- or Frequency Shift Keying (FSK)-based signaling. The devices
can be connected to Japan's NTT PBX using 'Modem' DID lines. These
DID lines are used to deliver a called number to the PBX.
[0] = (Default) FSK-based signaling
[1] = DTMF-based signaling
Note: This parameter is applicable only to FXS interfaces.
This table parameter enables support for Japan NTT 'Modem' DID. FXS
interfaces can be connected to Japan's NTT PBX using 'Modem' DID
lines. These DID lines are used to deliver a called number to the PBX.
The DID signal can be sent alone or combined with an NTT Caller ID
signal.
The format of the ini file table parameter is as follows:
[EnableDID]
FORMAT EnableDID_Index = EnableDID_IsEnable, EnableDID_Port,
EnableDID_Module;
[\EnableDID]
Where,
IsEnable = Enables [1] or disables [0] (default) Japan NTT Modem
DID support.
Port = Port number.
Module = Module number.
For example:
EnableDID 0 = 1,1,2; (DID is enabled on Port 1 of Module 2)
Note: This parameter is applicable only to FXS interfaces.
Defines the time (in msec) elapsed between two consecutive polarity
reversals. This parameter can be used for DID signaling, for example,
E911 lines to the Public Safety Answering Point (PSAP), according to the
Bellcore GR-350-CORE standard (refer to the ini file parameter
Enable911PSAP).
The valid range is 0 to 4,294,967,295. The default is 200.
Notes:
This parameter is applicable to FXS and FXO interfaces.
For this parameter to take effect, a device reset is required.
Table 51-54: Automatic Dialing Parameters
Defines the prefix code for activating Call Forward Unconditional sent
to the softswitch.
The valid value is a string. By default, no value is defined.
Note: The string must be enclosed in single apostrophe (e.g., '*72').
856
Mediant 1000B Gateway & SBC
Description
Description
Document #: LTRT-27034

Advertisement

Table of Contents
loading

Table of Contents