The Flexible Timeouts feature provides a variety of timers in the Resident System Program to allow the
system to operate without initial programming. The system timers can be changed to meet customer
needs according to the system application requirements.
A Timer Class allows terminals and trunks to have different timers for the same feature. There are 16
timer Classes (0~15). The following table shows the Programs that are used depending on the Timer
Class used:
Timer
Timer
Class 0
Class 1~15
20-01-08
20-31-01
20-01-09
20-31-02
20-04-03
20-31-03
21-01-02
20-31-04
21-01-03
20-31-05
21-01-09
20-31-06
22-01-03
20-31-07

Flexible Timeouts

Title
Trunk Queuing Callback
Time
Callback / Trunk Queuing
Cancel Time
CAR/SIE/Virtual Extension
Delay Interval
Intercom Interdigits Time
Trunk Interdigits Time
Hotline Time Start Time
Ring No Answer Alarm
Time
Flexible Timeouts
Comment
Trunk Queuing callback rings an extension for this
time. Station Timer Class is referred by the station
that sets trunk queuing.
The system cancels an extension Callback or
Trunk Queuing request after this time. Station
Timer Class is referred by the station that sets an
extension Callback or Trunk Queuing.
If CAR/VE is set for Delayed Ringing (Program
15-11-01), ring the covering extension after this
time. Station Timer Class is referred by the station
assigned to CAR/VE.
When placing Intercom calls, users must dial each
digit during this time. Station Timer Class is
referred by stations. Trunk Timer Class is referred
by DID/Automatic Answer Trunk/E&M trunks.
When placing CO calls, users must dial each digit
during this time. Station Timer Class is referred by
stations. Trunk Timer Class is referred by DID/
Automatic Answer Trunk/E&M trunks.
A Ringdown extension automatically calls its
programmed destination after this time. Station
Timer Class is referred by the station which sets
Hotline.
If a trunk rings a key telephone longer than this
time, the system changes the ring cadence. This
indicates to the user that the call has been ringing
too long. Trunk Timer Class is referred by the
trunk.