Electra Elite IPK II
20-13-06
Class of Service Options (Supplementary Service) – Automatic Off-Hook Signaling
(Automatic Override)
Program 20-02-03 and Program 20-13-06 set the conditions under which a Hotline, Reverse
Voice Over or DSS Console key indicates that an extension is busy. With condition 1 in the
following chart, the BLF LED is on only when both extension line appearances are busy. In
conditions 2~4, the BLF LED is on when one line appearance is busy.
1
BLF is on for extension receiving a voice announced Intercom call.
20-06-01
Class of Service for Extensions
Assign a Class of Service to an extension (1~15).
20-08-19
Class of Service Options (Outgoing Call Service) – Hot line for SPK
0 = Off
1 = On
20-11-06
Class of Service Options (Hold/Transfer Service) – Unscreened Transfer (Ring Inward
Transfer)
0 = Off
1 = On
20-11-11
Class of Service Options (Hold/Transfer Service) – Automatic On-Hook Transfer
0 = Off
1 = On
22-01-01
System Options for Incoming Calls – Incoming Call Priority
Determine if intercom calls or trunk calls have answer priority when both are ringing
simultaneously (0 = Intercom Call Priority, 1 = Trunk Call Priority). Refer to Program 15-02-22 for
light conditions.
30-05
DSS Console Lamp Table
If required, customize the system DSS Console flash rates. This table also affects DSS/Hotline
key lights for multiline terminals.
Hotline
Program 20-13-06
1
1
2
1
3
0
4
0
Program 20-02-03
0
1
0
1
Document Revision 4C
1
BLF
Busy
Status
Status
Off
No
On
Yes
On
Yes
On
Yes