NEC Electra Elite IPK II System User Manual page 615

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Electra Elite IPK II
10-29-06
SIP Server Information Setup – Registrar IP Address
Define the Registrar IP Address. The carrier may provide an IP address. In most cases, a
domain name is used so this entry is left at the default.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.225.255.254
(Default: 0.0.0.0)
10-29-07
SIP Server Information Setup – Registrar Port Number
Define the Registrar Port Number (0~65535).
(Default: 5060)
10-29-11
SIP Server Information Setup – Registrar Domain Name
Define the Registrar Domain Name (normally provided by the SIP carrier).
Example: SIPconnect-sca@L0.cbeyond.net
Entries: 128 characters maximum
(Default: None)
10-29-15
SIP Server Information Setup – Registration Expiry (Expire) Time
Define the Registration Expire time – the time (120~65535 seconds) allowed to register with the
SIP carrier. This should stay at default.
(Default: 3600)
SIP Server Status
90-10-01
System Alarm Setup – Alarm Type
Defines alarm type 14 and 60.
Alarm 14 – CPU-LAN Link Error (IP Layer 1)
Assign a Major or Minor alarm status to for the LAN link. This program also assigns whether or
not the alarm is displayed to a key telephone and whether or not the alarm information is
reported to the predefined destination.
Alarm 60 – SIP Registration Error Notification
Assign a Major or Minor alarm status to for the SIP Registration Error. This program also assigns
whether or not the alarm is displayed to a key telephone and whether or not the alarm
information is reported to the predefined destination.
90-10-14
System Alarm Setup – CPUII-LAN Link Error (IP Layer 1)
Assign a Major or Minor Alarm status to for the LAN link. This program also assigns whether or
not the alarm is displayed to a key telephone and whether or not the alarm information is
reported to the predefined destination.
90-10-60
System Alarm Setup – SIP Registration Error Notification
Assign a Major or Minor Alarm status to for the SIP Registration Error. This program also
assigns whether or not the alarm is displayed to a key telephone and whether or not the alarm