20-11-21
Class of Service Options (Hold/Transfer Service) – Restriction for Tandem Trunking on
Hang Up
Deny (1) an extension user ability to set up a tandem call automatically when they hang up.
(default: 0)
20-11-22
Class of Service Options (Hold/Transfer Service) – Restricted Unsupervised Conference
Enable (1)/Disable (0) an extension user ability to initiate an unsupervised conference.
(default: 0)
20-13-08
Class of Service Options (Supplementary Service) – Conference
Enable (1)/Disable (0) the extension ability to initiate a conference.
(default: 1)
20-13-10
Class of Service Options (Supplementary Service) – Barge-In Monitor
Set whether an extension should be able to Barge-In to a call and talk (1) or just monitor the call
(0).
(default: 0)
24-02-07
System Options for Transfer – Trunk-to-Trunk Transfer Release Warning Tone
This timer (0~64800 seconds) starts when a trunk begins talking with another trunk (for
example: Trunk-to-Trunk Transfer, outgoing from trunk, Tandem Trunking).
(default: 1800)
24-02-10
System Options for Transfer – Disconnect Trunk-to-Trunk
This timer (0~64800 seconds) starts after the Trunk-to-Trunk warning tone is heard.
(default: 0)
25-07-07
System Timers for VRS/DISA – Ling Conversation Warning Tone Time
Determine the time (0~64800 seconds) a DISA caller or a Tandem Trunking conversation can
talk before the Long Conversation tone is heard.
(default: 3600)
25-07-08
System Timers for VRS/DISA – Long Conversation Disconnect
This timer (0~-64800 seconds determines the time the system waits before disconnecting a call
after the Long Conversation tone is heard.
(default: 10)
Tandem Trunking Method B – Tandem Trunking with Transfer Key
14-01-04
Basic Trunk Data Setup – Transmit Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-05
Basic Trunk Data Setup – Receive Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-13
Basic Trunk Data Setup – Trunk-to-Trunk Transfer
For each trunk, enter 1 to enable loop supervision.
15-07-01
Programmable Function Keys
Assign a function key for Transfer (code 06).
Tandem Trunking (Unsupervised Conference)