NEC Electra Elite IPK II System User Manual page 610

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Document Revision 4C
21-17-01
IP Trunk (SIP) Calling Party Number Setup for Trunk
Assign the Caller Party Number for each IP trunk. The assigned number is sent to the central
office when the caller places an outgoing call. If the Calling Party Number is assigned by both
PRG 21-17 and PRG 21-18/PRG 21-19, then the system uses the entry in PRG 21-18/PRG
21-19.
Entries: 1~0,
(Default: None)
21-19-01
IP Trunk (SIP) Calling Party Number Setup for Extension
Assign the Calling Party Number for each extension. The assigned number is sent to the central
office when the caller places an outgoing call. If the Calling Party Number is assigned by both
Program 21-17 and Program 21-18/Program 21-19, the system uses the data in Program 21-18/
Program 21-19.
Entries: 1~0,
(Default: None)
SIP CODEC Trunk
84-13-01
SIP Trunk CODEC Information Basic Setup – G.711 Audio Frame Number
Set the G.711 Audio Frame Number.
Entries: 2~3
(Default: 2)
84-13-02
SIP Trunk CODEC Information Basic Setup – G.711 Voice Activity Detection Mode
Enable (1)/Disable (0) the G.711 VAD Detection Mode.
(Default: 0)
84-13-03
SIP Trunk CODEC Information Basic Setup – G.711 Type
Define the G.711 type.
Entries: 0 = A-law, 1 = -law
(Default: 1)
84-13-04
SIP Trunk CODEC Information Basic Setup – G.711 Jitter Buffer (min)
Set the minimum (0~200 ms) G.711 Jitter Buffer.
(Default: 20)
84-13-05
SIP Trunk CODEC Information Basic Setup – G.711 Jitter Buffer (Average)
Set the average (0~200 ms) G.711 Jitter Buffer type.
(Default: 40)
84-13-06
SIP Trunk CODEC Information Basic Setup – G.711 Jitter Buffer (max)
Set the maximum (0~200 ms) G.711 Jitter Buffer.
(Default: 60)
2 - 586
, # (to equal up to 16 digits)
, # (to equal up to 16 digits)
Electra Elite IPK II
IP Trunk (SIP) – MG16