NEC Electra Elite IPK II System User Manual page 755

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Electra Elite IPK II
34-02-01
E&M Tie Line Class of Service
Assign the Tie Line Class of Service (1~15). Use Program 20-14-01 to set the Tie Line Class of
Service options. You cannot use Program 20-06 ~ Program 20-17 to assign Class of Service to
Tie Lines.
(default: 1)
34-03-01
Trunk Group Routing for E&M Tie Lines
Assign the trunk group route chosen when a user seizes a Tie Line and dials 9. Set Trunk Group
Routing in Program 14-06-01. If the system has ARS, dialing 9 accesses ARS.
Options:
Route Table Number (0~100
0 = No Setting
(default: 1)
34-04-01
E&M Tie Line Toll Restriction Class
If the system uses Toll Restriction, enter a Toll Restriction Class (1~15) for each Tie Line. The
system uses the class you enter in Program 21-05-01. You cannot use Program 21-04 to assign
Toll Restriction to Tie Lines.
(default: 2)
34-05-01
Tie Line Outgoing Call Restriction
Build a restriction matrix for trunk calls placed over a Tie Line. For each Tie Line trunk group,
Enable (0)/Disable (1)) outgoing access to each CO trunk group.
(default: 0)
34-06-01
Add/Delete Digit for E&M Tie Line – Delete Digit
Some Tie Line networks pass the location number and extension number to the remote side. If
the system should ignore these digits, use this program to define the number of digits which
should be deleted (0~255, 255 deletes all digits) for a call.
(default: 0)
34-06-02
Add/Delete Digit for E&M Tie Line – Additional Dial Digits
If a Tie Line network requires additional digits to reroute the call to a location, enter the digits for
the location which should be added to the received digits (up to four digits).
(default: No Setting)
34-07-01
through
34-07-05
E&M Tie Line Timer
Define the system timers (0~64800 seconds) as needed for use with the Tie Line trunks
(default: 3 for 01, 0 for 02, 3 for 03, 0 for 04, and 30 for 05)
34-08-01
Toll Restriction Data for E&M Tie Lines
Define the toll restriction data (up to 10 digits) for E&M Tie Lines if required. This should be
defined if toll restriction is enabled in Program 21-05-13.
(default: No Setting
Multiple Trunk Types
Document Revision 4C
2 - 731

Hide quick links:

Advertisement

Table of Contents
loading